summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorDragos Ciprian Nedelcu <Dragos.Ciprian.Nedelcu@enea.com>2021-10-11 15:50:05 +0200
committerMiruna Paun <mrpa@enea.se>2021-10-14 17:49:23 +0100
commit84a45f22bba2e2e114184da39e2ee5bcf1c3ca29 (patch)
tree31b577b547b4d8fa4ba24a3af3b85422b7531b9a
parent7f0300cf95ac8f5592a6c43792b5b6470b69aaaf (diff)
downloadnfv-access-documentation-feature_CPDX-3562.tar.gz
Redundant management communication documentationfeature_CPDX-3562
Change-Id: I45eb901995c7344785b40df1f6b013a9bf36b486 Signed-off-by: Dragos Ciprian Nedelcu <Dragos.Ciprian.Nedelcu@enea.com>
-rw-r--r--doc/book-enea-edge-getting-started/doc/installation_guide.xml50
-rw-r--r--doc/book-enea-edge-release-info/doc/main_changes.xml14
2 files changed, 60 insertions, 4 deletions
diff --git a/doc/book-enea-edge-getting-started/doc/installation_guide.xml b/doc/book-enea-edge-getting-started/doc/installation_guide.xml
index da62568..42d1800 100644
--- a/doc/book-enea-edge-getting-started/doc/installation_guide.xml
+++ b/doc/book-enea-edge-getting-started/doc/installation_guide.xml
@@ -948,12 +948,30 @@ of=/dev/sdb bs=4M conv=fsync</programlisting>
948 948
949 <itemizedlist> 949 <itemizedlist>
950 <listitem> 950 <listitem>
951 <para>Select a WAN interface to use as the management network 951 <para>Select a WAN interface to use as the primary management network
952 interface. This interface is used by the Enea Edge Management 952 interface. This interface is used by the Enea Edge Management
953 application to communicate with the uCPE device.</para> 953 application to communicate with the uCPE device.</para>
954 </listitem> 954 </listitem>
955 955
956 <listitem> 956 <listitem>
957 <para>Select a WAN interface to use as the secondary management network
958 interface. This interface acts as a backup for the primary interface
959 and is used by the Enea Edge Management application to communicate with
960 the uCPE device if the communication through the primary management
961 interface fails. This configuration is optional (i.e. it can be left
962 empty). This interface is used only if Device Call Home communication
963 is enabled. For more details concerning Device Call Home, please
964 see <olink
965 targetdoc="book_enea_edge_getting_started"
966 targetptr="device_callhome_nat">Device Call Home Connection for
967 Deployment behind NAT in the <xi:include
968 href="../../s_docbuild/olinkdb/pardoc-names.xml"
969 xmlns:xi="http://www.w3.org/2001/XInclude"
970 xpointer="element(book_enea_edge_getting_started/1)" /></olink>
971 Manual.</para>
972 </listitem>
973
974 <listitem>
957 <para>Plug in additional WAN interfaces (if applicable) and 975 <para>Plug in additional WAN interfaces (if applicable) and
958 provide their Layer 3 configuration. An interface can be 976 provide their Layer 3 configuration. An interface can be
959 configured in <literal>dhcp</literal> or 977 configured in <literal>dhcp</literal> or
@@ -1197,12 +1215,38 @@ of=/dev/sdb bs=4M conv=fsync</programlisting>
1197 <title>uCPE Device Monitorization and Control</title> 1215 <title>uCPE Device Monitorization and Control</title>
1198 1216
1199 <para>Once the uCPE device is connected to the Enea Edge Management 1217 <para>Once the uCPE device is connected to the Enea Edge Management
1200 application, it is ready for central management. Two important functions 1218 application, it is ready for central management. Redundant management
1219 communication support is present on the uCPE device. Two important functions
1201 available in the Enea Edge Management GUI are alarm checking and resource 1220 available in the Enea Edge Management GUI are alarm checking and resource
1202 allocation. Additionally, the device can be rebooted, the factory settings 1221 allocation. Additionally, the device can be rebooted, the factory settings
1203 can be restored or simply the Enea Edge Management Agent service can be 1222 can be restored or simply the Enea Edge Management Agent service can be
1204 restarted.</para> 1223 restarted.</para>
1205 1224
1225 <section id="redundant_mgmt_com">
1226 <title>Redundant Management Communication</title>
1227
1228 <para>Redundant management communication support minimizes the risk of
1229 losing management connection by allowing the configuration of two
1230 interfaces (preferably from two different ISPs) as management
1231 interfaces.</para>
1232
1233 <para>During installation of Enea Edge Runtime on the device using the
1234 Web-installer application, the user can optionally configure a
1235 secondary management interface. The secondary management interface
1236 is used only if the Device Call Home option is enabled when adding
1237 the device in the Enea Edge Management application.</para>
1238
1239 <para>The secondary interface acts as a backup for the primary interface.
1240 Connection to the Enea Edge Management application is continuously
1241 monitored. If an issue is detected with the connection through the primary
1242 interface then the device will (try to) automatically connect using the
1243 secondary interface (<literal>fail-over</literal> operation). Once the
1244 issue has been resolved (i.e. the Enea Edge Management application is
1245 again reachable using the primary interface) the connection will
1246 automatically switch to using the primary interface
1247 (<literal>fail-back</literal> operation).</para>
1248 </section>
1249
1206 <section id="check_alarms"> 1250 <section id="check_alarms">
1207 <title>Checking Alarms</title> 1251 <title>Checking Alarms</title>
1208 1252
@@ -1300,4 +1344,4 @@ of=/dev/sdb bs=4M conv=fsync</programlisting>
1300 </note> 1344 </note>
1301 </section> 1345 </section>
1302 </section> 1346 </section>
1303</chapter> \ No newline at end of file 1347</chapter>
diff --git a/doc/book-enea-edge-release-info/doc/main_changes.xml b/doc/book-enea-edge-release-info/doc/main_changes.xml
index 629a892..c84dde7 100644
--- a/doc/book-enea-edge-release-info/doc/main_changes.xml
+++ b/doc/book-enea-edge-release-info/doc/main_changes.xml
@@ -58,6 +58,18 @@
58 xpointer="element(book_enea_edge_getting_started/1)" /></olink> 58 xpointer="element(book_enea_edge_getting_started/1)" /></olink>
59 Manual.</para> 59 Manual.</para>
60 </listitem> 60 </listitem>
61
62 <listitem>
63 <para><remark>CPDX-3562</remark>Added redundant management communication
64 support in Enea Edge Runtime. For more details please see <olink
65 targetdoc="book_enea_edge_getting_started"
66 targetptr="redundant_mgmt_com">Redundant Management Communication
67 in the <xi:include
68 href="../../s_docbuild/olinkdb/pardoc-names.xml"
69 xmlns:xi="http://www.w3.org/2001/XInclude"
70 xpointer="element(book_enea_edge_getting_started/1)" /></olink>
71 Manual.</para>
72 </listitem>
61 </itemizedlist> 73 </itemizedlist>
62 74
63 <para><emphasis role="bold">Improvements:</emphasis></para> 75 <para><emphasis role="bold">Improvements:</emphasis></para>
@@ -218,4 +230,4 @@
218 This could affect existing custom scripts using Python 2 syntax. Please 230 This could affect existing custom scripts using Python 2 syntax. Please
219 update these scripts accordingly in order to run in a Python 3 environment.</para> 231 update these scripts accordingly in order to run in a Python 3 environment.</para>
220 </section> 232 </section>
221</chapter> \ No newline at end of file 233</chapter>