Release-Specific Problems
Summary
Enea Ref
Eclipse Plug-Ins for Perf and Latencytop are not functioning properly on P2041RDB target.
LXCR-6936
QEMU cannot be launched from Eclipse environment.
LXCR-6997
Crosstap is not supported on LS1021a-IoT and QEMU targets.
LXCR-7110
LTTng kernel tracing from Eclipse does not work due to RSE connectivity problems.As a workaround, traces can be collected on target and visualized on Eclipse, after copying the files on the host system.
LXCR-7166
Latencytop is not supported on LS1021a-IoT target.
LXCR-7168
A limitation currently makes Powertop calibration not function properly on LS1021a-IoT target.
LXCR-7170
Due to optimization done by GCC when compiling the LS1021a-IoT kernel, some context variables may not have accurate debugging data and may not be accessible to Systemtap probes.
LXCR-7184
KGDB is not functioning properly on LS1021a-IoT target.The kernel sources are not present in the eSDK sysroot path and gdb will not be able to find the sources when debugging the kernel.
LXCR-7185